An unintentional roof fall occurred in the H1TG section at 49 wall in the 1 to 2 crosscut into #2 entry migrating into 2 to 3 entry. The fall measured approximately 66 Long x 24 Wide x 16 High. No injuries resulted from the accident. The immediate roof consisted of laminated shale material plus adverse geological conditions contributed to the failure.