# FALL OF ROOF OR BACK
> MSHA accident `220211160029` · 04/16/2021 · Consol Pennsylvania Coal Company LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol Pennsylvania Coal Company LLC
- **Mine:** [3607416](https://api.ai-analytics.org/mine/3607416)
## Narrative

An unintentional roof fall occurred in the G2 Longwall section 2-3 crosscut at 39 wall Spad# 107+10. The fall was approximately 16' wide x 50' long x height unknown.  The immediate roof consisted of laminated shale type material. Adverse geological conditions contributed to the failure. The fall was just at the longwall face at the time the fall occurred. 

---