Employee went into the 1490 stope to look at the ground and identified a fall of ground in the back that extended past the anchorage zone of the ground support. The stope was not currently active but was accessible. The fall occurred approximately 30' past the intersection in the right side of the heading. The back was supported with 6' split sets and 8' inflatable rock bolts.