← MSHA accidents

HOISTING

220211530007 · 06/01/2021 · Sunrise Coal, LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
Hallador Energy Company
Operator
Sunrise Coal, LLC
Mine
1202394

Narrative

The elevator would not run in inspection mode in the up direction. During the troubleshooting the elevator became inoperative at 11:40am. During the investigation it was found that the wires in the jacketed cable to the pendant controller were broken.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown