# FALL OF ROOF OR BACK
> MSHA accident `220211950002` · 07/11/2021 · Consol Pennsylvania Coal Company LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol Pennsylvania Coal Company LLC
- **Mine:** [3607230](https://api.ai-analytics.org/mine/3607230)
## Narrative

An unintentional roof fall occurred in 9L section. The fall occurred at 17 wall crosscut, approx halfway into the crosscut between #1 & 2 entry through #2 & in the crosscut 2-3.  The fall was approx 120' long by 16' high & 16' wide.  A site specific mine plan was submitted to rehab the area. *Adverse geological conditions caused the immediate strata to separate & subsequently fail.

---