220212240005 · 08/10/2021 · Crimson Oak Grove Resources LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
—
Mine experience
— years

Operator

Controller (parent)
ACNR Holdings, Inc
Operator
Crimson Oak Grove Resources LLC
Mine
0100851

Narrative

The NP Hoist was found to have a fault from the rope slip sensor. The sensor was checked and not working. The hoist was taken out of service until the sensor could be changed. The sensor was changed, the hoist was inspected, and placed back into service. MSHA was notified on site and via the hotline.