# FALL OF ROOF OR BACK
> MSHA accident `220212700010` · 09/23/2021 · Consol Pennsylvania Coal Company LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FALL OF ROOF OR BACK
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** CONSOL Energy Inc
- **Operator:** Consol Pennsylvania Coal Company LLC
- **Mine:** [3607416](https://api.ai-analytics.org/mine/3607416)
## Narrative

An unintentional roof fall occurred in the G2 Longwall inby 11 crosscut #3 entry, approximate spad 122+10.52. The fall was approximately 15' Long X 8.5' Wide X 16.5' height. The immediate roof consisted of laminated shale type material. Adverse geological conditions contributed to the failure. The fall was just at the longwall face at the time the fall occurred.

---