An unplanned roof fall occurred in the 4 west area at 26 x-cut. Adverse geological conditions caused the roof to separate and break. The roof fell 10ft from the track entry (#3 entry) through the crosscut to the belt, bridged over the belt entry and continued falling in the crosscut from the belt (#2 entry) towards the adjacent entry (#1 entry).