← MSHA accidents

FALL OF ROOF OR BACK

220220050014 · 12/31/2021 · Westmoreland San Juan Mining LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
Westmoreland Mining Holdings LLC
Operator
Westmoreland San Juan Mining LLC
Mine
2902170

Narrative

LW Shearer was cutting into the TG. Roof failed around 2 roof bolts, adjacent to Shield 176, the last shield on the face. Fall was estimated to be 4 ft. wide, 8 ft. long and 8 ft. high. The entry remained open. The fall is reported because it went above the anchorage of the installed roof supports. Ventilation was unaffected. The fall was immediately reported via the hotline.

Source

Authoritative
MSHA Open Government Data
Machine