# FIRE
> MSHA accident `220220530001` · 02/16/2022 · Graymont (PA) Inc.
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** FIRE
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Graymont Ltd
- **Operator:** Graymont (PA) Inc.
- **Mine:** [3606468](https://api.ai-analytics.org/mine/3606468)
## Narrative

Scale ring in Kiln 7 broke apart and created ash dust, which entered the cooler. The hot dust flowed through the cooler belt feeder and onto the cooler belt, which ignited due to the high temperature. Damage was limited to the cooler belt, head pulley, some rollers, and nearby electrical wires/cables.

---