# ELECTRICAL
> MSHA accident `220220660014` · 03/04/2022 · Hooker Creek Companies, LLC
## Details
- **Degree of injury:** NO DYS AWY FRM WRK,NO RSTR ACT
- **Classification:** ELECTRICAL
- **Accident type:** Flash burns (electric)
- **Occupation:** Front-end loader, Scraper-loader operator, Pan operator, Payloader, Scraper rig operator
- **Activity:** Electrical maintenance
- **Injury source:** ELECTRICAL APPARATUS,NEC
- **Nature of injury:** ELECT.ARC BURN-NOT CONTAC
- **Body part:** FACE, MULTIPLE PARTS
- **Days lost:** 0
- **Mine experience:** 2.96 years
## Operator
- **Controller:** Howard M  Day
- **Operator:** Hooker Creek Companies, LLC
- **Mine:** [3502491](https://api.ai-analytics.org/mine/3502491)
## Narrative

Miners were switching the belt motor from reverse to forward on the Thunderbird under belt conveyor. Two miners were inside Switch Van One, one miner was switching the wires to reverse the motor. The other miner was acting as an observer and communication relay. While doing so there was an arc flash inside of the electrical box. 

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*