Miner was operating LR1033 in New Fold escape drift when turbo caught on fire. Miner deployed fire suppression system, it did not put the fire out. Suppression system possibly malfunctioned or did not operate due to wet streams being too concentrated. Miner then used 10lb extinguisher to suppress flames. Miner was taken to local hospital for evaluation and released the same day.