Main water pump at mine had blockage. Employees of the mine along with one contractor employee were taking the pump apart to remove the blockage. Heat/steam had built up pressure in the pump unknowingly and released when the bolts were removed from the flange on the pump. Result was 2nd degree burn on 25% of body of contractor employee.