In muck bay #2 located in 4041 Barrel, shotcrete support came off the right rib while mucking the face. The measurement estimated to be 47' in length. The back & left rib were still supported. No injury occurred nor damage to equipment. Due to shotcrete separation, based on some corroded bolts & air slack, the muck bay couldn't be used till a plan was developed to rehab the area