# HOISTING
> MSHA accident `220231230001` · 04/29/2023 · Nevada Gold Mines LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Barrick Nevada Holding LLC; Newmont USA Limited
- **Operator:** Nevada Gold Mines LLC
- **Mine:** [2602286](https://api.ai-analytics.org/mine/2602286)
## Narrative

The 3rd shaft hoist went down due to a blown fuse in the control circuit for the PT.  Heat in the room combined with the tight tolerance of the PT fuses was the root cause.  The fuse was repaired and the AC unit is also being repaired to prevent reoccurrence. The hoist was back up at approximately at 10:30 P.M.  MSHA was notified within time.

---