← MSHA accidents

FALL OF ROOF OR BACK

220232220009 · 08/05/2023 · Consol Pennsylvania Coal Company LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consol Pennsylvania Coal Company LLC
Mine
3607230

Narrative

An unintentional roof fall occurred in the #1 entry of 6 South between 108 and 109 x-cut. Adverse geological conditions in the form of a ""cutter"" due to horizontal stress, ran up the left rib causing the roof strata to separate above the primary bolts. In later days this fall extended inby to approximately 80ft out by the 110 x-cut. No injury or equipment damage to report.

Source

Authoritative
MSHA Open Government Data
Machine