An unintentional roof fall occurred in the 6 South area of the mine at 104 x-cut between the #7 to 8 entry. The fall measured approx. 40 ft long by 16 ft wide 7-10 ft high. It is believed that horizontal stresses caused by a stream valley affected the roof strata causing a separation that ultimately fell. No injury or equipment damage as a result of this incident.