An unintentional roof fall occurred in 2 East 4 to 5 entry at 96 wall. The fall measured 6' high by 35' long by 11' wide. The immediate roof consisted of laminated shale material. Adverse geological conditions and horizontal stresses contributed to the failure. No injuries occurred because of this incident and no compliance issues were found.