The conditions contributing to the roof fall on the 9-Left LW section in the #1 entry between 39xc and 40xc that was approximately 55 feet in length by 19 feet in width by 8 to 10 feet in height, comprised of entering a transition area of a rider seam coming down into the mine bench and a sandstone transition coming in above the area.