# HOISTING
> MSHA accident `220241560021` · 06/02/2024 · Nevada Gold Mines LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** Barrick Nevada Holding LLC; Newmont USA Limited
- **Operator:** Nevada Gold Mines LLC
- **Mine:** [2602286](https://api.ai-analytics.org/mine/2602286)
## Narrative

4703 hoist alarmed to having a DCB low voltage fault. During the troubleshooting phase, it was found that the loop contactor wiring was brittle causing the wiring to short out on the metal framing of the loop contactor box. 

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*