# HOISTING
> MSHA accident `220241620009` · 06/05/2024 · Crimson Oak Grove Resources LLC
## Details
- **Degree of injury:** ACCIDENT ONLY
- **Classification:** HOISTING
- **Accident type:** Accident type, without injuries
- **Occupation:** —
- **Activity:** —
- **Injury source:** —
- **Nature of injury:** —
- **Body part:** —
- **Days lost:** —
- **Mine experience:** — years
## Operator
- **Controller:** ACNR Holdings, Inc
- **Operator:** Crimson Oak Grove Resources LLC
- **Mine:** [0100851](https://api.ai-analytics.org/mine/0100851)
## Narrative

The SP Elevator was taken out of service due to a rag getting in the governor rope sheave causing the rope to come off of the sheave.  The rope was placed back on the sheave, slack removed from the rope, the elevator tested, and placed back in service.   

---
*Source: [MSHA Open Government Data](https://arlweb.msha.gov/OpenGovernmentData/) · AI Analytics · CC0 1.0*