# ELECTRICAL
> MSHA accident `220242220029` · 07/31/2024 · United Salt Carlsbad LLC
## Details
- **Degree of injury:** DAYS AWAY FROM WORK ONLY
- **Classification:** ELECTRICAL
- **Accident type:** Contact with electrical current
- **Occupation:** Electrician, Lineman
- **Activity:** Electrical maintenance
- **Injury source:** ELECTRICAL APPARATUS,NEC
- **Nature of injury:** ELECT SHOCK,ELECTROCUTION
- **Body part:** BODY SYSTEMS
- **Days lost:** 5
- **Mine experience:** 17.06 years
## Operator
- **Controller:** Texas United Corp
- **Operator:** United Salt Carlsbad LLC
- **Mine:** [2901043](https://api.ai-analytics.org/mine/2901043)
## Narrative

On July 31, 2024, an experience plant electrician was assigned the task of repairing a portable conveyor. At approx. 8:28 am the conveyor was cleaned and moved into the shop for repairs. The elec. replaced a 240 v. 4 wire plug. When conveyor was plugged into an outlet and start button was pushed, the elec. received a shock, the plug was wired incorrectly. Employee was eval. at ER.

---