# POWERED HAULAGE
> MSHA accident `220242630005` · 09/14/2024 · Teck Alaska Inc
## Details
- **Degree of injury:** NO DYS AWY FRM WRK,NO RSTR ACT
- **Classification:** POWERED HAULAGE
- **Accident type:** Struck against a moving object
- **Occupation:** Master mechanic, Foreman, Supervisor
- **Activity:** Machine maintenance
- **Injury source:** PASS CARS,PICKUP TRUCKS
- **Nature of injury:** FRACTURE,CHIP
- **Body part:** NECK
- **Days lost:** 0
- **Mine experience:** 1.31 years
## Operator
- **Controller:** Teck Resources Limited
- **Operator:** Teck Alaska Inc
- **Mine:** [5001545](https://api.ai-analytics.org/mine/5001545)
## Narrative

Mud on transmission linkage prevented shifting from park. Driver exited the running pickup, set chocks, then went under pickup. While cleaning linkage, driver accidentally separated the shift cable from the transmission linkage. The operator unknowingly moved linkage from park to reverse. The wheel chocks were not set tight against tire allowing contact with driver at right flank. 

---