An unintentional roof fall occurred in 3 East Mains #1 Entry 36 Wall. The fall is approximately 100' long / 16' wide / 20' high. There were no injuries as a result of this incident. Conditions contributing to the roof fall are adverse roof conditions and a shift of the strata causing the roof strata to separate above the anchorage.