← MSHA accidents

HOISTING

220242970044 · 10/14/2024 · U S Gypsum Company

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
USG Corporation
Operator
U S Gypsum Company
Mine
1200427

Narrative

During operation of hoisting rock, an encoder fault had occurred on the hoist, stopping operation. While trying to reset the fault by powering the system down per the instructions of the manufacturer, the drive would not power back on due to the plunger on the contacts not tripping, therefore not giving the reset feedback to the system.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown