An unplanned roof fall occurred outby in an intake air course of the B-Main. The fall occurred appx. 30'inby survey spad 788 in the #6 entry. Fall was appx. 20'long,19'wide with an unknown height. Exact cause is unknown however several geologic features are present in this mining area and have previously resulted in a roof fall in an adjacent submain .