← MSHA accidents

FALL OF ROOF OR BACK

220243320005 · 11/22/2024 · Wilson Creek Energy LLC

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
Mine experience
— years

Operator

Controller (parent)
Quintana Capital Group GP Ltd
Operator
Wilson Creek Energy LLC
Mine
3609893

Narrative

An unplanned roof fall occurred outby in an intake air course of the B-Main. The fall occurred appx. 30'inby survey spad 788 in the #6 entry. Fall was appx. 20'long,19'wide with an unknown height. Exact cause is unknown however several geologic features are present in this mining area and have previously resulted in a roof fall in an adjacent submain .

Source

Authoritative
MSHA Open Government Data
Machine