# EXPLODING VESSELS UNDER PRESSURE
> MSHA accident `220251200007` · 04/24/2025 · Mellott Company LLC
## Details
- **Degree of injury:** DYS AWY FRM WRK & RESTRCTD ACT
- **Classification:** EXPLODING VESSELS UNDER PRESSURE
- **Accident type:** Contact with hot objects or substances
- **Occupation:** Superintendent
- **Activity:** Observe operations
- **Injury source:** WATER
- **Nature of injury:** BURN OR SCALD (HEAT)
- **Body part:** MULTIPLE PARTS (MORE THAN ONE MAJOR)
- **Days lost:** 64
- **Mine experience:** 1.46 years
## Operator
- **Controller:** Jonathan  Schilowitz
- **Operator:** Mellott Company LLC
- **Mine:** [3610430](https://api.ai-analytics.org/mine/3610430)
## Narrative

Defective Radiator cap blew off water pump resulting with Burns on employees right side (Arm, armpit, back, stomach area).

---