The hoist tripped due to the gap on the right brake stand-2 upper caliper was detected on the hoist control system to be outside of tolerance at 2mm. The gap was checked and adjusted to 0mm at which time the hoist was reset and back operational. The Silver Shaft Hoist (primary) and 2 Shaft hoist (secondary) were operational throughout.