A Unplanned Roof Fall Occurred On NE-9 (#8 Section) At Crosscut Number 49 In The Long Crosscut Between The #2 Track Entry And The #3 Belt Entry. The Mine Roof Fell Above The Anchorage Point Of The Primary Roof Support. The Roof Fall Occurred Due To Undetected Separation With Laminations Above The Anchorage Point Of The Primary Roof Support Installed During Development.