The employee was holding the shaft with the crane. When EE raised the hoist, it moved faster than anticipated, causing the synthetic lifting strap to fail. This caused the hook block to jolt and become unattached to the rope cable, then falling to the floor. The hook block then struck the sync motor and then struck the employee's right middle and right ring finger.