A unintentional roof fall occurred in the #1 entry of 6 south @ 61 crosscut. The fall measured approx. 50ft long by 8ft high by 16ft wide. The fall occurred due to unconsolidated laminated shale above the primary anchorage zone. A shift in the adverse roof caused is to fall. Depth of cover 1020