An unintentional roof fall occurred at 105 xcut in 6 south area of the mine. This fall occurred in a belt line intersection. The fall measured approximately 50ft long by40ft wide by 20ft high. The fall was caused by adverse roof conditions created by two stream valley intersecting at this area. Depth of cover in the area was 750 ft and was originally mined in March of 2022