On 08/18/2025 @ 3:00 PM Geology teams entered XV 1457-320, where they heard ground support fail (1 split bolt). Geo Tech teams inspected the same day and ordered the heading shut down after the heading was bolted. On 08/19 mining crew completed ground support. No further access was granted until 09/08 when Geo Tech team entered to inspect, the FOG was discovered, MSHA was notified.