On 02/15/2026 an unintentional roof fall occurred On the P3-1 (Unit #3) at crosscut #18, entry #3 in the last open crosscut. The fall is approximately 20 foot in length, 30 foot wide and 8 foot thick. It seemed the water bearing sandstone interval came down to approximately 8 foot, causing the immediate roof to fail.