An unplanned roof fall occurred outby the section loading point above anchorage. The fall is located at #16 crosscut from the #7-#8 entries measuring approximately 90 feet long by 10 foot thick. Supplemental roof support was added in the adjacent entries, and the fall has been breakered off.