CPSC And Berko Announce Baseboard Heater Repair Program

CPSC Recall · 1996-02-15 · 96069

Recall

Number
96069
Date
1996-02-15

Products

Names
Berko baseboard heaters

Companies

Manufacturer(s)
Marley Engineered Products; Berko

Description

February 15, 1996 Release # 96-069 WASHINGTON, D.C. - CPSC, Berko Electric of Peru, Ind., is announcing the voluntary repair or replacement of approximately 1.5 million baseboard heaters. Wires inside the heaters may deteriorate, allowing electrical currents to flow to the utside steel air deflector cover. Arcing, or sparking, may occur, burning holes in the cover. As a result, a potential fire hazard exists. In addition, if the heaters are not properly grounded, an electrical shock could exist.Berko, a division of Marley Electric Heating, has received some 200 complaints of deteriorated wires and burned heater covers. To date, only minor property damage has been reported.This repair program affects only Berko heaters sold between January 1980 and March 1987 with model numbers that begin with "MBB," followed by four numbers, and ending in "M" (for example, "MBB2-524-M"). The tan-colored baseboard heaters are permanently installed units measuring two feet (500 watt) to ten feet (2500 watt) in length. The silver Berko identification label, which includes the model number, is located inside the heater on the right side, just below the steel air deflector. The black date code is printed directly on the heater, just to the right of the identifying label (for example, "FEB 22 85")To prevent a fire or electric shock, all of the potentially defective heaters should be repaired or replaced. Consumers who own Berko MBB...M series baseboard heaters should check for discoloration on the steel air deflector cover of the heater. If the cover is discolored, heaters should be disconnected immediately until repaired. Berko will either provide new wire to repair the heaters or provide a substantial discount towards the purchase of new heaters, depending on consumers' preference.Berko will provide free replacement crossover wire rated at 125 degrees centigrade rather than the 105 degree centigrade temperature of the original crossover wire. Detailed instructions for changing the wire

Source

Authoritative
CPSC recall page
Machine
JSON-LD · Markdown