← NHTSA ODI investigations

NHTSA SQ SQ00010

SQ · INCORRECTLY MOLDED MASTER FLOAT CHAMBER · Opened 2000-06-08 · Open

Investigation

Action number
SQ00010
Type
SQ
Open date
2000-06-08
Status
Open
Manufacturer
Brake Parts Inc.
Affected makes
BRAKE PARTS
Affected components
SERVICE BRAKES, HYDRAULIC
Affected model years
2000
Affected (make, year) variants
2

Summary

IN APRIL 2000, BRAKE PARTS INC. INITIATED A CUSTOMER NOTIFICATION CAMPAIGN TO ADDRESS CERTAIN BRAKE MASTER CYLINDERS THAT WERE IMPROPERLY MOLDED AND ASKED FOR THEM TO BE RETURNED.THE LETTER IDENTIFIED TWO POSSIBLE CONDITIONS THAT MIGHT OCCUR IF THE MASTER CYLINDER IS OUT OF SPECIFICATION:THE FLOAT CHAMBER MAY NOT FILL WITH BRAKE FLUID CAUSING THE BRAKE WARNING LIGHT TO ILLMINATE, AND THE FLOAT CHAMBER WILL NOT DRAIN BRAKE FLUID UPON DEMAND, CAUSING THE BRAKE WARNING LIGHT TO REMIN OFF WHEN IT SHOULD ILLUMINATE.BOTH SCENARIOS APPEAR TO HAVE SAFETY CONSEQUENCES.THE PURPOSE OF THIS SQ IS TO DETERMINE THE EXTENT OF THE PROBLEM EXPERIENCE, CONSEQUENES, AND IF A SAFETY RECALL IS WARRANTED.