← NHTSA quarterly recall completion

NHTSA Recall 16V294000

Pump Strainer could fail due to Weak Soldering · Kovatch Mobile Equipment Corp. · Recalled 2016-06-14 · 34.26% complete

Latest status

Recall number
16V294000
Manufacturer
Kovatch Mobile Equipment Corp.
Defect
Pump Strainer could fail due to Weak Soldering
Recall date
2016-06-14
Affected units
108
Remedied (latest)
37 (34.26%)
Unreachable owners
0
Removed from recall
0
Latest report
2017-10-18 (2017-3)
Quarters reported
6

Quarterly progress

PeriodAffectedRemediedUnreachableRemoved% CompleteReported
2016-21083002.78%2016-10-26
2016-31083002.78%2016-10-26
2016-41083002.78%2017-01-23
2017-1108340031.48%2017-04-11
2017-2108360033.33%2017-07-05
2017-3108370034.26%2017-10-18

Source

Authoritative
NHTSA recall page
Machine
JSON-LD · Markdown