# NHTSA Recall 19V710000 — Completion Reports
> **Incorrectly Plumbed Unit Outrigger Valve** · Altec Industries Inc. · Recalled 2019-11-25
## Latest status
- **Affected units:** 275
- **Remedied:** 194 (70.55%)
- **Unreachable owners:** 0
- **Removed from recall:** 0
- **Latest report:** 2021-04-12 (2021-1)
- **Quarters reported:** 6
## Quarterly progress
| Period | Affected | Remedied | Unreachable | Removed | Completion % | Reported |
|--------|----------|----------|-------------|---------|--------------|----------|
| 2019-4 | 275 | 67 | 0 | 0 | 24.36% | 2020-01-10 |
| 2020-1 | 275 | 139 | 0 | 0 | 50.55% | 2020-04-14 |
| 2020-2 | 275 | 160 | 0 | 0 | 58.18% | 2020-07-13 |
| 2020-3 | 275 | 168 | 0 | 0 | 61.09% | 2020-10-12 |
| 2020-4 | 275 | 188 | 0 | 0 | 68.36% | 2021-01-11 |
| 2021-1 | 275 | 194 | 0 | 0 | 70.55% | 2021-04-12 |
## Source
- [NHTSA recall page](https://www.nhtsa.gov/recalls?nhtsaId=19V710000)
---
*AI Analytics · CC0 1.0*