# Electrocutions, electric shocks at Shasta
> OSHA SIR `20171111099` · 11/18/2017 · COLUMBUS, OHIO
## Severity
- **1 hospitalization**
- **Body part:** BODY SYSTEMS
- **Nature of injury:** Electrocutions, electric shocks
## Cause
- **Event:** Direct exposure to electricity, unspecified
- **Source:** Power cords, electrical cords, extension cords
## Employer
- **Name:** Shasta
- **Location:** 4685 Groveport Road, COLUMBUS, OHIO, 43207
- **NAICS:** 312111
- **Jurisdiction:** 1
## Narrative

On November 18, 2017, a temporary employee was attempting to disconnect a power supply cord for a conveyor line to unjam it. The electrical power supply cord exterior was damaged and the employee contacted unprotected live parts. The employee was electrocuted.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · AI Analytics · CC0 1.0*