# Amputations at DAP Products Inc.
> OSHA SIR `20191010683` · 10/12/2019 · DALLAS, TEXAS
## Severity
- **1 amputation**
- **Body part:** Fingertip(s)
- **Nature of injury:** Amputations
## Cause
- **Event:** Caught in running equipment or machinery during maintenance, cleaning
- **Source:** Bottling, canning, filling machinery
## Employer
- **Name:** DAP Products Inc.
- **Location:** 13555 Jupiter Road, DALLAS, TEXAS, 75238
- **NAICS:** 325520
- **Jurisdiction:** 1
## Narrative

An employee was clearing a jam on a stem cartridge filling machine when his left index finger was caught between a pneumatic plunger and the frame of the machine, resulting in a fingertip amputation. The air source was not locked/tagged out at the time of the incident.

---
*Source: [OSHA Severe Injury Reports](https://www.osha.gov/severe-injury-reports) · AI Analytics · CC0 1.0*