A ROOF FALL OCCURRED AT 10:15AM ON 1/13/05 AT X-CUT 86 ENTRY 3 JMAINSOUTH. FALL WAS IN 4-WAY INTERSECTION THAT HAD BEEN MINED 1/4/91. FALL 20' LONG X 30' WIDE X 10' HIGH. AREA WAS SUPPORTED WITH 8' FULL RESIN BOLTS AND PROPS. NO INJURY OCCURRED BUT MAIN LINE BELT WAS COVERED UP. FALL WILL BE CLEANED UP.