← MSHA accidents

FALL OF ROOF OR BACK

220051540040 · 05/25/2005 · Consolidation Coal Company

Details

Degree of injury
ACCIDENT ONLY
Classification
FALL OF ROOF OR BACK
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
CONSOL Energy Inc
Operator
Consolidation Coal Company
Mine
4404856

Narrative

An unintentional roof fall was discovered by mine rescue teams at approximately 11:28am in the #1 entry on Grassy Creek Mains starting approx 120ft inby survey station # 15977 and extending inby to survey station 3 16519, size of fall is approx 20ft wide x 920ft long x height unknown. No injuries or equipment was involved. This fall will not be cleaned up.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown