A fall occured 300 feet outby the face, 60 feet outby spad No. 249 in No. 6 entry at a 4-way intersection. The roof has multiple cracks and prior to the fall, timbers and heitzmann jacks had been installed. The fall was 60 ft. long, 20 ft. wide and 6-8 ft. thick.