← MSHA accidents

HOISTING

220060410043 · 02/06/2006 · Lyons Salt Company

Details

Degree of injury
ACCIDENT ONLY
Classification
HOISTING
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Peter E Powell
Operator
Lyons Salt Company
Mine
1400413

Narrative

Normal Hoisting made when a fuse blew on the main hoist motor cooling fan. This shut the hoist down and set the brakes. The fuse controlling the blower fan is located in the dc 2000 thy ristr control panel and is set up to shut the motor down and set the brakes on hoist if this blower fan fuse blows. This is a 4 amp fuse.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown