← MSHA accidents

IGNITION OR EXPLOSION OF GAS OR DUST

220061370027 · 05/01/2006 · Exeter Coal Corporation

Details

Degree of injury
ACCIDENT ONLY
Classification
IGNITION OR EXPLOSION OF GAS OR DUST
Accident type
Accident type, without injuries
Occupation
Activity
Injury source
Nature of injury
Body part
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Cumberland Resources Corporation
Operator
Exeter Coal Corporation
Mine
4407106

Narrative

A possible methane ignition occurred on the 1-left off North Mains section (mmu 002-0). The second cut inby the last open crosscut (No.6 heading) was being mined. The miner operator was cutting down on the face & when the cutter bits struck the sandstone bottom, a possible frictional ignition occurred.

Source

Authoritative
MSHA Open Government Data
Machine
JSON-LD · Markdown