← MSHA accidents

IGNITION OR EXPLOSION OF GAS OR DUST

220061370027 · 05/01/2006 · Exeter Coal Corporation

Details

Degree of injury
ACCIDENT ONLY
Classification
IGNITION OR EXPLOSION OF GAS OR DUST
Accident type
Accident type, without injuries
Occupation
—
Activity
—
Injury source
—
Nature of injury
—
Body part
—
Days lost
0
Mine experience
— years

Operator

Controller (parent)
Cumberland Resources Corporation
Operator
Exeter Coal Corporation
Mine
4407106

Narrative

A possible methane ignition occurred on the 1-left off North Mains section (mmu 002-0). The second cut inby the last open crosscut (No.6 heading) was being mined. The miner operator was cutting down on the face & when the cutter bits struck the sandstone bottom, a possible frictional ignition occurred.

Source

Authoritative
MSHA Open Government Data
Machine