A methane ignition occured in the face of the #2 entry on the 0-Panel section (00-7 MMU), approx. 60 ft inby survey station #25117. The ignition occured while the continuous miner was cutting sandstone bottom. The ignition occured int he lower right hand corner of the face. Flame duration was approx. 30 seconds and was extinguished with a wash down hose. There were no