An unintentional roof fall was discovered in the #7 entry at #27 break (Intake). Size of fall was estimated to be 55'L x 20'W x 6'H. The area had been supported with 4' fully grouted resin bolts with additional support consisting of 10' cable bolts. No injuries, no equipment caught, ventilation was not interrupted. Fall will not be cleaned up.