An unintentional roof fall was discovered in the #9 entry at #29 break (Intake). Size of fall was estimated to be 30'L x 20'W x 5'H. The area had been supported with 4' resin bolts. No injuries, no equipment caught, ventilation was not interrupted. Fall will not be cleaned up.