An unintentional roof fall occurred in the #4 entry at spad #9491. The fall was estimated to be 4 ft high by 18 ft wide by 60 ft long. This area was bolted with 4 ft resin bolts with 10 ft cable bolts in the intersection. No injuries, track & belt was caught, ventilation was not interupted. The fall will be cleaned up.